EL20N
Main characteristics
- Electrolysis type: PEM (Proton exchange membrane, caustic free)
 - Number of cell stacks: 1
 
Hydrogen gas production
- Max. nominal hydrogen flow: 1.881 kg/h
 - Hydrogen flow range: 10 -100%
 - Operating pressure: 15 – 40 barg (217-580 psig)
 - Hydrogen purity (before gas purification): > 99.9%; < 25 ppm O2; H2O saturated
 - Hydrogen purity (after gas purification): As per ISO 14687
 
Electrical requirements
- Voltage: 3 x 400 VAC ± 10% (3Ph+N) / 3 x 480 VAC ± 10% (3Ph+N)
 - Frequency: 50 Hz ± 5% / 60 Hz ± 3%
 - Total installed power : 122 kW
 - Stack Consumption (*): ≤ 54.2 kWh/kg H2
 - AC power Consumption (BoP + stack) (*): ≤ 62.8 kWh/kg H2 (118.1 kW Nominal Power @ BoL, 100% load)
 
(*) This value could be lower, depending on final configuration
Feed Water - Demi Water (optional Water Treatment Plant is not included)
- Consumption: < 1 L/Nm3 H2
 - Conductivity: > 10 MΩcm (< 0.1 uS/cm); TOC < 30 ppb
 - Pressure: 2-3 barg (29-43 psig)
 - Temperature: +5 ºC to + 40 ºC (+41 ºF to +104 ºF)
 
Control system
- PLC: Fully automated and unattended with 7″ color touch screen
 - Communication: Modbus TCP/IP or Profinet (RJ45 port)
 
Environmental conditions
- Ambient temperature range: +5 ºC to + 45 ºC (+41 ºF to +113 ºF)
 - Humidity: 0 to +95% (non-condensing)
 - Air ventilation: Available from a non-hazardous area
 - Installation area: Indoor/Outdoor
 
Dimensions and weight
- Dimensions (LxWxH): 20 ft container (6.0m x 2.4m x 2.9m) (19.7ft x 7.9ft x 9.5ft)
 - Approx. weight: 6,000 kg (13,227 lb)
 
Standards & regulations
- Compliance*: CE, ISO 22734-1 / NFPA 2-2020 & NFPA 70
(*) GreenH can accommodate local standards if required 
Other characteristics
- Duty cycle: 100% (24/7)
 - Start-up time (from stand-by): < 30 sec
 - Cold start time: < 20 min
 - Nitrogen System: For each purge, consumption is <0.2 kg at >1 barg (to be supplied by the customer)
 - Instrumentation Air System: Consumption 7 Nm3/h at 10 barg (to be supplied by the customer) Class V as per ISO 8573.1
 
Always included
All our products do always incorporate:
- Hydrogen cooling system
 - Emergency shutdown system
 - Overpressure relief system
 - Redundancy on critical safety parameters
 - Uninterruptible Power Supply (UPS)
 - Heat management (no cooling water is needed)
 - Virtual Private Network (VPN) connection
 
Additional Options
All our products can include:
- Oxygen processing system
 - Hydrogen purification system (SAE J2719 September 2011)
 - Water treatment system
 - Extreme environmental conditions package (low and high temp)
 Hydrogen Mass Flow Measure & Purity Measure (H2O & O2 Sensors)